LEDVANCE OPTOTRONIC FIT CS G3 - OT FIT 40/220…240/1A0 CS

LEDVANCE OPTOTRONIC FIT CS G3 - OT FIT 40/220…240/1A0 CS


Specifications
Details

LEDVANCE OPTOTRONIC FIT CS G3 - OT FIT 40/220…240/1A0 CS

  • OT FIT 40/220…240/1A0 CS

Product family features
  • Lifetime: up to 50,000 h (temperature at max. tc) 
  • Cable clamp kit for independent mounting

Product family benefits
  • Higher quality of light thanks to low output ripple current
  • High flexibility due to four different output currents
  • Small housing for flexible luminaire designs
  • High efficiency

Areas of application
  • Suitable for downlights, spotlights and LED panels
  • Suitable for luminaires of protection classes I and II

Electrical data
  • Nominal input voltage : 220…240 V
  • Mains frequency : 50/60 Hz
  • Input voltage AC : 198…264 V 
  • Total harmonic distortion : < 10 % 1)
  • Power factor λ : 0.98 
  • Efficiency in full-load : 90 % 2)
  • Device power loss : 4.9 W 3)
  • Protective conductor current : <0.7 mA
  • Inrush current : ≤ 35 A 4)
  • Max. ECG no. on circuit breaker 10 A (B) : 11
  • Max. ECG no. on circuit breaker 10 A (C) : 19
  • Max. ECG no. on circuit breaker 16 A (B) : 19
  • Max. ECG no. on circuit breaker 16 A (C) : 31
  • Max. ECG no. on circuit breaker 25 A (B) : 29
  • Surge capability (L/N-Ground) : 2 kV
  • Surge capability (L-N) : 1 kV
  • Nominal output voltage : 25…42 V / 30...42V 5)
  • U-OUT (working voltage) : 60 V
  • Nominal output current : 800 / 900 / 950 / 1050 mA
  • Output current tolerance : ±7.5 %
  • Default output current : 1050 mA
  • Output ripple current (100 Hz) : < 5 % 
  • Output PSTLM : ≤1
  • Output SVM : ≤0.4
  • Nominal output power : 20…44.1 W
  • Maximum output power : 44.1 W
  • Galvanic isolation : SELV
  • Galvanic isolation primary/secondary : SELV
  • Current set : DipSwitch
  1. At full load, 230 V, 50 Hz / see graphs
  2. at 230 V, 50 Hz
  3. At 230 V, Input power 49 W max.
  4. twidth = 200 µs (measured at 50 % Ipeak)
  5. 30 - 42V @ 1050 mA

Dimensions & weight
  • Mounting hole spacing, length : 88.0 mm
  • Mounting hole spacing, width : 34.0 mm
  • Product weight : 110.00 g
  • Cable cross-section, input side : 0.5…1.5 mm² 
  • Cable cross-section, output side : 0.5…1.5 mm² 
  • Wire preparation length, input side : 7…8 mm
  • Wire preparation length, output side : 7…8 mm
  • Length : 97.0 mm
  • Width : 43.0 mm
  • Height : 29.5 mm

Colors & materials
  • Casing material : Plastic

Temperatures & operating conditions
  • Ambient temperature range : -20…+50 °C
  • Maximum temperature at tc test point : 80 °C 
  • Max.housing temperature in case of fault : 110 °C
  • Temperature range at storage : -20…80 °C
  • Permitted rel. humidity during operation : 5…85 % 1)
  1. Non-condensing

Lifespan
  • ECG lifetime : 50000 h 1)
  1. At maximum Tc = 80°C / 10% failure rate

Additional product data
  • Predecessor EAN : 4052899435650

Capabilities
  • Dimmable : No
  • Overheating protection : Automatic reversible
  • Overload protection : Automatic reversible
  • Short-circuit protection : Automatic reversible
  • No-load proof : Yes
  • Intended for no-load operation : No
  • Max. cable length to lamp/LED module : 2.0 m 1)
  • Suitable for fixtures with prot. class : I / II
  • Type of connection, input side : Push terminal
  • Type of connection, output side : Push terminal
  • Suitable for through-wiring : No
  • Control interface : -
  • Detection angle (Light sensor) : -
  • Detection angle (PIR) : -
  • Number of channels : 1
  1. Output wires must be routed as close as possible to each other

Programming
  • Programming device : DIPswitch

Certificates & standards
  • Approval marks – approval : CCC / CE / RCM / ENEC 05
  • Standards : Acc. to IEC 61347-1/Acc. to IEC 61347-2-13/Acc. to / IEC 62384/Acc. to CISPR 15/Acc. to IEC 61000-3- / 2/Acc. to IEC 61000-3-3/Acc. to IEC 61547
  • Type of protection : IP20
  • Protection class : I,II