MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-54

MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-54


Specifications
Details

MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-54

  • HLG-60H-54

Features
  • Universal AC input / Full range (up to 305VAC)
  • Built-in active pfc function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • IP67 / IP65 design for indoor or outdoor installations
  • Class 2 power unit 
  • Three in one dimming funvtion (1~10Vdc or PWM signal or resistance)
  • Suitable for LED lighting and moving sign applications
  • Compliance to worldwide safety regulations for lighting 
  • SUitable for dry / damp / wet locations
  • 5  years warranty (Note. 10)

SPECIFICATION
  • Model : HLG-60H-54
Output 
  • DC voltage : 54V
  • Constant current region : 32.4 ~ 54V
  • Rated current : 1.12A
  • Rated power : 62.1W
  • Ripple & noise (max.) : 300mVp-p
  • Volatge adj. range : 49 ~ 58V
  • Current adj. range : Can be adjusted by internal potentiometer A type only / 0.69 ~ 1.15A
  • Voltage tolerance :  ±1.0%
  • Line regulation :  ±0.5%
  • Load regulation :  ±0.5%
  • Setup, rise time : 500ms, 80 ms at full load      230VAC/115VAC
  • Hold up time(typ.) : 16ms/230VAC 16ms/115VAC at full load
Input
  • Voltage range : 90 ~ 305VAC 127 ~ 431VDC 
  • Frequency range : 47 ~ 63Hz
  • Power factor : PF > 0.98/115VAC, PF > 0.95/230VAC, PF > 0.92/277VAC @ full load 
  • Total harmonic distortion : THD < 20% when output loading  ≧ 60%/115VAC/230VAC input and output loading ≧75%/277VAC input
  • Efficiency : 90%
  • AC current : 0.64AA/115VAC / 0.32A/230VAC / 0.3A/277VAC
  • Inrush current : Cold start 55A (width=265 μs measured at 50% peak)/230VAC
  • Leakage current : <0.75mA / 277VAC
Protection
  • Over current : 95 ~ 108% / Protection type : Constant current limiting, recovers automatically after fault condition is removed
  • Short circuit : Hiccup mode, recovers automatically after fault condition is removed
  • Over voltage : 59 ~ 68V / Shut down o/p voltage, re-power on to recover
  • Over temperature : Shut down o/p voltage, re-power on to recover
Environment
  • Working temp. : -40 ~ +770°C 
  • Working humidity : 20 ~ 95% RH non-condensing
  • Storage temp. humidity : -40 ~ +80°C, 10 ~ 95% RH
  • Temp. coefficient : ± 0.03%/​ °C (0~60°C)
  • Vibration : 10 ~ 500Hz, 5G 12min,/1 cycle, period for 72min. each along X, Y, Z axes
Safety & EMC
  • Safety standards : UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1, EN60335-1
  • Withstand voltage : I/P-O/P:3.75KVAC   I/P-FG:2KVAC    O/P-FG:0.5KVAC
  • Isolation resistance : I/P-O/P,I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH
  • EMC emission : Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3
  • EMC immunity : Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
Others
  • MTBF : 338K hrs min. MIL-HDBK-217F (25 )
  • Dimension : 171*61.5*36.8mm (L*W*H)
  • Packing : 0.73Kg; 20pcs/15.6Kg/0.9CUFT

View more about MEANWELL 60W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-60H SERIES - HLG-60H-54 on main site