MEANWELL 185W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-185H SERIES - HLG-185H-15
Specifications
Details
MEANWELL 185W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-185H SERIES - HLG-185H-15
-
HLG-185H-15
- Universal AC input / Full range (up to 305VAC)
- Built-in active pfc function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- IP67 / IP65 design for indoor or outdoor installations
- Class 2 power unit
- Three in one dimming funvtion (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- SUitable for dry / damp / wet locations
- 5 years warranty (Note. 10)
SPECIFICATION
- Model : HLG-185H-15
- DC voltage : 15V
- Constant current region : 7.5 ~ 15V
- Rated current : 11.5A
- Rated power : 172.5W
- Ripple & noise (max.) : 150mVp-p
- Volatge adj. range : 13.5 ~ 17V
- Current adj. range : Can be adjusted by internal potentiometer A type only / 5.75 ~ 11.5A
- Voltage tolerance : ±2.0%
- Line regulation : ±0.5%
- Load regulation : ±1.5%
- Setup, rise time : 1000ms,50ms/115VAC 500ms,50ms/230VAC at full load ; B type 1000ms,200ms/115VAC
- Hold up time(typ.) : 16ms at full load 230VAC / 115VAC
- Voltage range : 90 ~ 305VAC 127 ~ 431VDC
- Frequency range : 47 ~ 63Hz
- Power factor : PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to ''Power Factor Characteristic'' curve)
- Total harmonic distortion : THD < 20% when output loading ≧ 60%/115VAC/230VAC input and output loading ≧75%/277VAC input
- Efficiency : 92%
- AC current : 12V : 1.8A / 115VAC 0.8A / 230VAC 0.7A / 277VAC / 15V ~ 54V : 2.1A / 115VAC 0.9A / 230VAC 0.8A / 277VAC
- Inrush current : COLD START 65A(t =445 s measured at 50% I ) at 230VAC
- Leakage current : <0.75mA / 277VAC
- Over current : 95 ~ 108% / Protection type : Constant current limiting, recovers automatically after fault condition is removed
- Short circuit : Hiccup mode, recovers automatically after fault condition is removed
- Over voltage : 18 ~ 21V / Shut down o/p voltage, re-power on to recover
- Over temperature : Shut down o/p voltage, re-power on to recover
- Working temp. : -40 ~ +770°C
- Working humidity : 20 ~ 95% RH non-condensing
- Storage temp. humidity : -40 ~ +80°C, 10 ~ 95% RH
- Temp. coefficient : ±0.03%/℃ (0 ~ 50 ℃ )
- Vibration : 10 ~ 500Hz, 5G 12min,/1 cycle, period for 72min. each along X, Y, Z axes
- Safety standards : UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ;design refer to UL60950-1, TUV EN60950-1
- Withstand voltage : I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- Isolation resistance : I/P-O/P,I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH
- EMC emission : Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
- EMC immunity : Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
- MTBF : 192.2K hrs min. MIL-HDBK-217F (25 )
- Dimension : 228*68*38.8mm (L*W*H)
- Packing : 1.15Kg; 12pcs/14.8Kg/0.8CUFT
View more about MEANWELL 185W SINGLE OUTPUT SWITCHING POWER SUPPLY - HLG-185H SERIES - HLG-185H-15 on main site